Service

WUFI moisture analysis

Checks that a proposed wall or roof can still dry out, so new insulation doesn’t lead to mould or rot.

WUFI graph for understanding wall insulation strategy for a phased retrofit of an 1800s sandstone detached house near Preston

Why it matters

Why moisture modelling matters

When insulation is added to a structure, it keeps the heat inside the building – if this insulation has been put on the inside of the wall it will consequently make parts of the structure colder than they used to be, and less able to dry out. A dynamic moisture simulation is therefore sometimes necessary to check the hygrothermal properties of a proposed construction in order to see that moisture problems will not be created over time.

This is done using WUFI, a software that models moisture content within a structure over a period of years, and it takes all moisture sources into account including a major source in the UK – driven rain. Standard steady-state moisture modelling (Glaser method) factors in only vapour diffusion rather than all moisture sources, and cannot check the impact over time. WUFI by contrast is a very useful tool for making decisions about what will likely be a safe build-up for a particular location.

Carrying out this type of modelling is not always necessary, but it would typically be a good idea in cases internal wall insulation is proposed for a solid wall and where the u-value will be below 0.4 W/m²K, or in other constructions where we might want to check moisture and mould risk (for example if planning to fully fill existing rafters that already have a modern breather membrane externally). What we want to check is whether there is any risk of mould or wood rot at certain critical places (for example, at the insulation to wall interface, or on the cold side of rafters or joist ends).

When it is worth doing

How it works

Getting the material data right

The modelling itself requires a good handle on the material properties of the construction. For brick walls however, this can pose a problem since the database of UK bricks within WUFI is limited, and yet the absorption characteristics of bricks in our old buildings can vary a lot, even within the same building! So knowing these characteristics (rather than taking too many assumptions) is important, as well as the other aspects that affect moisture risk such as orientation and the local climate, all of which will affect how much insulation is safe to add.

In addition, the airtightness layer on the warm side of the construction can also affect whether a proposed build-up is going to be safe – even an intelligent membrane is not always going to be the most suitable choice for a solid wall for example. Therefore sometimes it will be prudent to core out some brick or stone samples for analysis in a laboratory, in order to get the precise data for the modelling. An alternative is to use Karsten Tubes in situ, but this will be less precise – however it will still give some indication as to the range of absorptivity and will allow similar materials in the database to be used in the analysis.

On site and in the model

From the wall to the model

Karsten tube test of brick absorptivity on a brick wall
Karsten Tube test of brick absorptivity.
Graph of Karsten Tube results showing water absorbed by different bricks over time
Results from the Karsten Tube test which can help inform the modelling process.
WUFI graph showing water content over time in an internal insulation layer
A graph showing water content over time from a WUFI analysis of an internal insulation layer.

Get in touch

Ask about WUFI moisture analysis

Tell me a little about your house or project and I will come back to you.

Prefer to talk? Call 07814 788 846 or email ericfewster@coldproof.co.uk.