Service
Measures heat loss at junctions such as window reveals, with annotated drawings showing how to build them.
Why it matters
Junctions between things tend to be the weak spots in a construction in terms of energy efficiency, and there is a tendency in both design and installation for a lack of detail about how to maintain insulation and airtightness continuity here. Standard architectural details are often not adequate, and then contractors are left to do their best on site to make it work while also not knowing the best materials to use.
For a low energy building design, we need to know what the heat loss is from these junctions, which can be a significant additional heat loss in addition to the assumed u-values for the wall, floor and roof surfaces alone. Also at certain junctions (such as window reveals) there can be a condensation and mould risk where the surface temperature drops below dewpoint, and so we need to also check surface temperatures stay above 15 degrees Celsius at the coldest spot. Typical junctions that need modelling in a retrofit include wall to roof, wall to floor, window jambs, door thresholds and party wall junctions.
I check that the internal temperature at the coldest inside surface of any junction is above 15°C.
How it works
The modelling is done using Therm, which creates a two-dimensional view of the heat loss given a certain geometry – the output is a psi-value which is what would normally be entered into PHPP (the energy modelling software) to check the effect on the whole building energy demand. Where there is a condensation risk, different iterations are re-run to reduce that risk (for example for windows, by adding additional insulation on the reveal to raise the temperature).
Following this, an annotated drawing is made showing what needs to be used in practice for constructing the junction in order to maintain both insulation and airtightness continuity. While this modelling is done as part of the retrofit master planning work, it can also be carried out as a standalone service either to model a proposed build-up, or to check something that has already been built.
From model to site
Get in touch
Tell me a little about your house or project and I will come back to you.
Prefer to talk? Call 07814 788 846 or email ericfewster@coldproof.co.uk.